Part Number Hot Search : 
P600KG 2812D D54ACT F12W3 PA1214 FN3557 13003A Y8C24
Product Description
Full Text Search
 

To Download NLP40-7605 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 NLP40 Series
* * * * * * *
Single, dual and triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50W AC/DC Universal Input Switch Mode Power Supplies 1 4.25 x 2.5 x 1.15 inch package (1U applications) Smallest industry package Overvoltage and short circuit protection 40W with free air convection EN55022, EN55011 conducted emission level B EN61000-4-2, -3, -4, -5, -6 immunity compliant UL, VDE and CSA safety approvals
The NLP40 series is a 40W universal input AC/DC power supply on a 4.25 x 2.5 inch card with a maximum component height of 1.15 inches for use in 1U applications. This product is the smallest standard 40W package in the industry making the series ideal for communication applications with space constraints where a standard 5 x 3 inch card solution is not suitable. The NLP40 provides 40W of output power with free air convection cooling which can be boosted to 50W with 20CFM of air. Standard features include overvoltage and short circuit protection. The series, with full international safety approval and the CE mark, meets conducted noise EN55022 level B and has immunity compliance to EN61000-4-2,-3,-4, -5, -6. The NLP40 series is designed for use in low power data networking, computer and telecom applications such as hubs, routers, POS terminals, LCD projectors, cable modems and PABX's. This list is not exclusive as the generic feature set of the NLP40 series with industry standard output configurations provides a solution for most low power applications including many industrial applications.
All specifications are typical at nominal input, full load at 25C unless otherwise stated
2 YEAR WARRANTY
SPECIFICATIONS
OUTPUT SPECIFICATIONS Total regulation (Line and load) Rise time Transient response Temperature coefficient Overvoltage protection Short circuit protection Minimum output current INPUT SPECIFICATIONS Input voltage range (See Note 9) Input frequency range Input surge current Safety ground leakage current Input current Input fuse 120VAC, cold start 230VAC, cold start 120VAC, 60Hz 230VAC, 50Hz 120VAC 230VAC UL/IEC127
(10)
GENERAL SPECIFICATIONS 2.0% 5.0% 1.0s, max. 5.0% max. dev., 1ms rec. to 1.0% 0.02%/C Hold-up time Efficiency Isolation voltage Switching frequency Approvals and standards (See Note 8) Weight MTBF MIL-HDBK-217F Input/output Input/chassis Fixed 120VAC 230VAC 12ms @ 40W 20ms @ 40W 75% typical 3000VAC 1500VAC 65kHz, 5kHz EN60950, IEC950, UL1950 VDE0805, CSA C22.2 No. 950 200g (7.06oz) 150,000 hours min.
Main output Auxiliary outputs At turn-on Main output 25% step at 0.1A/s
Main outputs Cyclic operation Single Multiple
135%, 15% Continuous 0A (See Note 5)
ENVIRONMENTAL SPECIFICATIONS Universal input 90 to 264VAC 120 to 370VDC 47Hz to 440Hz 15A max. 30A max. 0.2mA 0.4mA 1.4A rms 0.7A rms 250VAC H 3.15A Thermal performance (See Notes 6, 7, 9) Operating ambient, 0C to +70C (see derating curve) Non-operating -40C to +70C 50C to 70C ambient, Derate to convection cooled 50% load 0C to 50C, ambient, 40W convection cooled 0C to 50C ambient, 50W 20CFM forced air Peak (0C to +50C, 60s) (See Note 2) Non-condensing Operating Non-operating 5Hz to 500Hz per MIL-STD-810E 5% to 95% RH 10,000 feet max. 30,000 feet max. 2.4G rms peak 516.4 Part IV
Relative humidity Altitude Vibration (See Note 4) Shock
EMC CHARACTERISTICS Conducted emissions Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity
EN55022, FCC part 15 EN55022, FCC part 15 EN61000-4-2, level 3 EN61000-4-2, level 3 EN61000-4-5, level 3 EN61000-4-4, level 3 EN61000-4-3, level 3 EN61000-4-6, level 3
Perf. Perf. Perf. Perf. Perf. Perf.
level B level A criteria 1 criteria 1 criteria 1 criteria 1 criteria 1 criteria 1
File Name: NLP40.PDF Rev: 01 Jan 2000
NLP40 Series
OUTPUT VOLTAGE +5V (IA) +12V (IB) -12V (IC) +5V (IA) +15V (IB) -15V (IC) +12V (IA) -12V (IB) +5V (IA) +12V (IB) 5V 12V 15V 24V 48V Notes MAX
(1)
Single, dual and triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50W AC/DC Universal Input Switch Mode Power Supplies 2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT CURRENT RIPPLE PEAK 5.0A 3.0A 1.0A 5.0A 2.0A 1.0A 2.2A 2.2A 5.0A 3.0A 10A 4.5A 3.6A 2.5A 1.1A
(2) (3)
TOTAL REGULATION
MODEL NUMBER NLP40-7608
(5)
FAN
(1)
4.0A 2.0A 0.2A 4.0A 1.6A 0.2A 1.8A 1.8A 4.0A 2.0A 8.0A 3.3A 2.6A 1.6A 0.8A
4.5A 3.0A 0.5A 4.5A 2.0A 0.5A 2.1A 2.1A 4.5A 3.0A 9.0A 4.0A 3.3A 2.0A 1.0A
50mV 120mV 120mV 50mV 150mV 150mV 120mV 120mV 50mV 120mV 50mV 120mV 150mV 240mV 300mV
2.0% 5.0% 5.0% 2.0% 5.0% 5.0% 2.0% 5.0% 2.0% 5.0% 2.0% 2.0% 2.0% 2.0% 2.0%
NLP40-7610
(5)
NLP40-7627
(5)
NLP40-7629
(5)
NLP40-7605 NLP40-7612 NLP40-7615 NLP40-7624 NLP40-7617
Output Power (Watts) Maximum output power is 40W for natural convection cooling. With 20CFM fan cooling, the maximum output power is 50W. 50W 2 Peak output current lasting less than 60 seconds with duty cycle less than 5%. During peak loading, output voltage may exceed total reg. limits. 20 CFM FORCED AIR COOLING 3 Figure is peak-to-peak. Output noise measurements are made across a 40W 50MHz bandwidth using a 12 inch twisted pair, terminated with a 47F capacitor. 4 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4G rms 5Hz to 500Hz. 5 For multiple output units (except -7627) to maintain stated regulation then: NATURAL 25W 0.25 IA / IB 5, for IB > 0.3A CONVECTION 0.50 IA / IB 5, for IB < 0.3A COOLING 20W For maximum output current I(C) on triple output models, i.e. for IC = IMax., IA min. 0.5A and IA IB. For NLP40-7627 only, to maintain stated regulation then: 0.5 IA / IB 2. 6 For optimum reliability, no part of the heatsink should exceed 120C, and no semiconductor case temperature should exceed 130C. 7 CAUTION: Allow a minimum of 1 second after disconnecting line power 0C 10C 20C 30C 40C 50C 60C 70C when making thermal measurements. 8 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product. 9 When the input voltage is <90VAC the operating range is 0C to +40C. 10 For system EMI compliance, a ground choke may be required before connecting the ground wire to the INPUT OUTPUT PIN CONNECTIONS chassis. It is recommended that this ground choke be PIN CONNECTIONS J2 SINGLE DUAL TRIPLE placed as close as possible to the systems AC inlet to eliminate noise pick-up in the system. J1
1
DERATING CURVE
Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6
+Vout +Vout +Vout
V (B) V (A) V (A)
V (B) V (A) V (A)
Pin 1 Pin 2 Pin 3
AC Line No Pin AC Neutral P1
Return Return Return
Return Return Return
Return Return V (C)
Pin 1
Safety Ground
www.artesyn.com
File Name: NLP40.PDF Rev: 01 Jan 2000
NLP40 Series
Single, dual and triple output
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 40-50W AC/DC Universal Input Switch Mode Power Supplies 3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
4.25 (107.95) 4.00 (101.60) J1 N L F1 1 0.125 (3.175)
2.50 (63.50) P1 T1 C5
J2
2.25 (57.15)
ALL DIMENSIONS IN INCHES (mm)
MAXIMUM COMPONENT HEIGHT 1.15 (29.21) TOLERANCE: .xxx 0.005" .xx 0.02"
Mounting Hole Diameter 0.138 (3.50) Typical
Input and output connectors
AC (J1) connector type Molex 26-60-4030 type. DC (J2) connector type Molex 26-60-4060 type.
Mating connectors
AC (J1) mating connector type Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp terminals. DC (J2) mating connector type Molex 09-50-3061 with Triurcon 6838 or equivalent crimp terminals. Note: The input and output connectors are the same as those used on NFS40, NFN40, NAL40 and NAN40.
International Safety Standard Approvals
VDE0805/EN60950/IEC950 File No. pending UL1950 File No. E136005 CSA C22.2 No. 950 File No. LR41062C
Data Sheet (c) Artesyn Technologies(R) 2002 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
www.artesyn.com
File Name: NLP40.PDF Rev: 01 Jan 2000


▲Up To Search▲   

 
Price & Availability of NLP40-7605

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X